A heating degree day (HDD) is a unit that measures how far the average outdoor temperature on a given day falls below a base temperature at which buildings are assumed to need no heating. In the United States the base is 65 degrees Fahrenheit, and elsewhere 18 degrees Celsius is common. The colder the day, the more heating degree days it records, and totals over a month or a season indicate how much energy was needed to keep buildings warm.
The measure was developed by engineers to estimate fuel use and is now a standard input for utilities, energy traders and weather risk markets. Its warm-weather counterpart is the cooling degree day, which measures the need for air conditioning. Heating degree days are published by national weather services, in the United States by the National Oceanic and Atmospheric Administration, using readings from official stations such as those in the Automated Surface Observing System.
Formula and example
The daily value is calculated as:
- is the base temperature, normally 65 degrees Fahrenheit.
- is the day's highest recorded temperature.
- is the day's lowest recorded temperature.
A day with a high of 50 and a low of 30 has an average of 40, so it records heating degree days. A day averaging 65 or more records zero; the value is never negative. Daily values are added to give a cumulative figure. If seven days have average temperatures of 40, 35, 50, 66, 30, 45 and 60, the daily values are 25, 30, 15, 0, 35, 20 and 5, and the week's total is 130.
Use in energy markets
Demand for space heating rises roughly in line with heating degree days, which makes them the main weather variable in forecasts of winter consumption of natural gas, heating oil, propane and electricity. Analysts often weight the figures by population or by the number of gas-heated homes in each region, so that cold weather in densely populated areas counts for more. A local distribution company uses them to plan purchases and to explain changes in sales from one year to the next.
Traders compare forecast totals with the average for the same dates over a long reference period. A forecast well above normal implies heavier withdrawals from gas storage and tends to lift prices at benchmarks such as Henry Hub, while a mild outlook has the opposite effect. Because forecasts change with each run of the weather models, shifts in the expected degree-day count for the next two weeks are among the most important short-term drivers of gas prices in winter.
Weather derivatives and event contracts
Heating degree days are the most common underlying for a weather derivative. The first such deals were arranged privately between energy companies in 1997, and exchange-traded contracts followed in 1999 on the Chicago Mercantile Exchange. A typical futures contract settles on the cumulative total for a named city over a calendar month or a winter season, with each index point worth a fixed sum of money.
Suppose a contract pays $20 per heating degree day and a gas distributor sells it at an index level of 900 to protect against a warm month. If the month turns out mild and the index settles at 840, the seller gains dollars per contract, which helps to offset lower gas sales. If the month is cold and the index settles at 960, the seller loses the same amount but sells more gas. Options and swaps on the index follow the same logic, often with a cap on the maximum payout.
Temperature thresholds also appear in each event contract on a prediction market that asks whether a city's temperature or degree-day total will exceed a stated level. All such instruments settle on officially published observations, not on any party's actual losses.
Limitations
- Simplified weather. The measure uses only the daily high and low. It ignores wind, humidity, cloud cover and the hour-by-hour path of temperature, all of which affect heating demand.
- Arbitrary base. A fixed base of 65 degrees does not suit every building. Well-insulated modern buildings begin to need heat at lower outdoor temperatures.
- Location mismatch. A contract settles on one weather station, often at an airport, while the hedger's customers are spread over a wider area. The gap between the two is a form of basis risk.
- Changing relationships. Improvements in energy efficiency, fuel switching and electrification alter the amount of energy used per degree day over time.
- Shifting normals. As a result of climate change, averages based on past decades may overstate the heating degree days to be expected in a typical winter.
Weather forecasts expressed as a range of outcomes, such as an ensemble forecast, are commonly used to judge how uncertain a projected degree-day total is.